Climatic Chamber KK 350

TECHNICAL DATA
air convectionforced
chamber capacity [l]322
working capacity [l]283
controllermicroprocessor PID
display7" full colour touch screen
TEMPERATURE AND HUMIDITY
temperature range [°C]0…+60
temperature resolution every … [°C]0,1
temperature variation at 25°C and 60%rH [+/-°C]*2,0
temperature protectionclass 3.3 to DIN 12880
relative humidity range [%]30…90 (see chart for details)
humidity resolution every … [%]1,0
humidity variation at 25°C and 60% rH [%rH]5,0
CHAMBER
door typedouble (external solid, internal glass) / external glass (option)
interior
Smart PROacid-proof stainless steel to DIN 1.4301
IG Smart PROacid-proof stainless steel to DIN 1.4301
housing
Smart PROpowder coated sheet
IG Smart PROstainless steel linen finish
overall dims [mm] /1/
width A660
height B2000
depth C990
internal dims [mm]
width D470
width D'510
height E1340
depth F500
height I1180
shelves (standard | max)3 | 11
max shelf workload [kg] /2/10
- reinforced shelf version (PW) [kg] /3/100
max unit workload [kg]100
weight [kg]125
ELECTRICAL PARAMETERS
voltage**230V 50-60Hz
nominal power [W]1850
refrigerantR290 / GWP=3
warranty24 months
manufacturerPOL-EKO

all the above technical data refer to standard units (without optional accessories)
* - variation (K) calculated for chamber as: K= +/- (T average max. - T average min.) / 2
** - other power supplies on request
1 - depth doesn't include 50 mm of power cable
2 - on uniformly loaded surface
3 - reinforced shelf

door with viewing window

Order number: */A

door with viewing window
Stainless steel wire shelf INOX

Order number: */P INOX

Stainless steel wire shelf INOX
Perforated shelf

Order number: */PP

Perforated shelf
Reinforced shelf

Order number: */PW

Reinforced shelf
Stainless steel cuvettes

Order number: KUW GN*/*

Stainless steel cuvettes
Phytotron system

Order number: */FIT

Phytotron system
FIT panels independent control

Order number: FIT/R3

FIT panels independent control
Internal socket

Order number: GNZ

Internal socket
Low water level sensor

Order number: KK/CP

Low water level sensor
Calibration and IQ, OQ, PQ qualification

Order number: BRT/*/L or IQ/OQ/PQ

Calibration and IQ, OQ, PQ qualification
Battery backup for display

Order number: BPP 12

Battery backup for display
Dry alarm contact

Order number: PORT ALARM

Dry alarm contact
LAN cable

Order number: LANK

LAN cable
Non-standard access port 20 mm

Order number: OCZ/20

Non-standard access port 20 mm
Additional access port 30 mm

Order number: OCZ/30

Additional access port 30 mm
Non-standard access port 60 mm

Order number: OCZ/60

Non-standard access port 60 mm
Non-standard access port 100 mm

Order number: OCZ/100

Non-standard access port 100 mm
Access control

Order number: KD

Access control

KK 350 Smart PRO