The brand new Smart PRO controllers are direct followers to the TOP+ controllers and will be available for the KK climatic chambers, IL cooled incubators, SL drying ovens, CL laboratory incubators, as well as the ST cooled incubators, CHL laboratory refrigerators, ZL laboratory freezers and ZLN-UT ultra-low freezers.

grupa urządzeń Smart PRO

Advantages of the Smart PRO controller:

  • large (7”), clear, full colour touch screen
  • LAN, USB ports and WiFi for communication and data transfer
  • multi-segment time and temperature programs
  • loop function up to 255 times or endless
  • adjustable start delay feature
  • adjustable ramps
  • recording of min, average and max temperature value for each segment
  • operating in temperature or time priority mode
  • fan speed control in the range of 0 … 100% or 10% … 100% (depending on the chamber capacity); and 50…100% for ST/CHL
  • temperature sensor fail alarm
  • possibility of temperature calibration by the User
  • power failure control system (program continued after restoring power)
  • overview of data in tabular and graphic form
  • visual and sound alarm
  • administrating functions for management
  • password protected log-in
  • internal memory for programs and data storage
  • operating with gloves on
  • event registry with user notifications
  • LabDesk software and user manual for direct download
  • Alarm Bar – quick visual information about device status
  • Quick Note – user can save messages (50 characters) in Smart PRO controller memory
  • Quick Change of parameters: temperature, humidity, time, air flap and fan

GLP supporting feature

  • possibility to create user accounts with rights and password assignment
  • 40 user programs memory
  • data registry – 10 000 data records for each user, possibility to display data on the screen in tabular or grahpic form
  • direct data download through USB port
  • event registry
smart-pro-ekran-en

All product data sheets with the Smart PRO controller can be found here.

Standard features – Smart PRO:

  • temperature range 0…+15°C
  • LabDesk software
  • ethernet cable
  • quality control protocol (at +4°C)
  • english instruction manual
  • temperature protection 3.2 class to DIN 12880
  • open door alarm
  • wheels in standard for models CHL 1200 and 1450
  • door lock
  • USB port to allow direct recording and data transfer onto a flash drive
  • LAN port
  • internal LED light
  • access port: Ø30 mm
  • solid door
  • temperature range: +5°C above ambient temp. … +100°C
  • ethernet cable
  • LabDesk software
  • USB port to allow direct recording and data transfer onto a flash drive
  • quality control protocol (at +37°C)
  • english instruction manual
  • temperature protection class 3.1 to DIN 12880
  • open door alarm
  • wheels in standard for models 400, 750, 1000
  • air-flap diameter for CL 15-180 Ø40 mm, for CL 240-1000 – Ø60 mm
  • USB ports for data transfer
  • LAN port for remote control
  • access port: Ø30 mm
  • wire stainless steel shelves
  • solid door, internal glass door
  • door lock
  • temperature range: 0°C above ambient temp. … +100°C/optionally -10°C up to 100°C
  • ethernet cable
  • LabDesk software
  • USB port to allow direct recording and data transfer onto a flash drive
  • quality control protocol (at +37°C)
  • english instruction manual
  • temperature protection class 3.3 to DIN 12880
  • open door alarm
  • wheels in standard for models 400, 750, 1000
  • USB ports for data transfer
  • LAN port for remote control
  • access port: Ø30 mm
  • wire stainless steel shelves
  • solid door, internal glass door
  • door lock
  • temperature range: 0°C above ambient temp. … +100°C/optionally -10°C up to 100°C
  • ethernet cable
  • LabDesk software
  • USB port to allow direct recording and data transfer onto a flash drive
  • quality control protocol (at +37°C)
  • english instruction manual
  • temperature protection class 3.3 to DIN 12880
  • open door alarm
  • wheels in standard for models 400, 750, 1000
  • USB ports for data transfer
  • LAN port for remote control
  • access port: Ø30 mm
  • wire stainless steel shelves
  • solid door, internal glass door
  • door lock
  • temperature range: -10°C …60°C, +10°C …+50°C (FIT option with light on)
  • ethernet cable
  • LabDesk software
  • quality control protocol (at +25°C, 60%rH)
  • english instruction manual
  • temperature protection class 3.3 to DIN 12880
  • open door alarm
  • automatic defrosting function
  • deionized water container
  • LAN port
  • access port: Ø30 mm
  • wire stainless steel shelves
  • USB port to allow direct recording and data transfer onto a flash drive
  • double door (external solid, internal glass)
  • door lock
  • wheels with brake
  • waste water container
  • temperature range: -10…+100°C
  • ethernet cable
  • LabDesk software
  • quality control protocol (at +25°C, 60%rH)
  • english instruction manual
  • temperature protection class 3.3 to DIN 12880
  • open door alarm
  • automatic defrosting function
  • deionized water container
  • LAN port
  • access port: Ø30 mm
  • wire stainless steel shelves
  • USB port to allow direct recording and data transfer onto a flash drive
  • double door (external solid, internal glass)
  • door lock
  • wheels with brake
  • waste water container
  • temperature range: +5°C above ambient temp. … +300°C
  • ethernet cable
  • LabDesk software
  • USB port to allow direct recording and data transfer onto a flash drive
  • quality control protocol (at +105°C)
  • english instruction manual
  • temperature protection class 3.1 to DIN 12880
  • open door alarm
  • wheels in standard for models 400, 750, 1000
  • air-flap diameter for SL 15-180 Ø40 mm, for SL 240-1000 – Ø60 mm
  • USB ports for data transfer
  • LAN port for remote control
  • access port: Ø30 mm
  • wire stainless steel shelves
  • solid door, internal glass door
  • door lock
  • temperature range +3…+70°C
  • ethernet cable
  • LabDesk software
  • quality control protocol (at +37°C)
  • english instruction manual
  • temperature protection 3.3 class to DIN 12880
  • open door alarm
  • wheels in standard for models ST 1200 and 1450
  • door lock
  • USB port to allow direct recording and data transfer onto a flash drive
  • LAN port
  • internal LED light
  • access port: Ø30 mm
  • wire stainless steel shelves
  • solid door
  • temperature range -86…-40°C
  • quality control protocol (at -80°C)
  • english instruction manual
  • ethernet cable
  • LabDesk software
  • LAN cable
  • access port: Ø20 mm
  • door lock
  • external solid door and internal solid door for each chamer
  • wheels
  • controller spare batteries in case of power failure – alarm output
  • additional port for installation of CO2 backup
  • temperature range -25…0°C for ZLN 85 and -40…0°C for ZLN-T 125, 200, 300
  • wire stainless steel shelves for ZLN 85 and perforated stainless steel for ZLN-T 125, 200, 300
  • quality control protocol (at -20°C)
  • english instruction manual
  • LabDesk software
  • LAN cable
  • ethernet cable
  • open door alarm
  • access port: Ø20 mm
  • door lock
  • solid door
  • USB ports for data transfer
  • internal memory to store up to 2046 data records
  • wheels in standard for ZLN-T 300